 TROUBLESHOOTING PROCEDURES BY ASSEMBEY. SERVICE MODE & DRIVE BOARD TROUBLESHOOTING


  1. SMPS-PDP TV: Can be located at the top center of the panel, look
    after back cover opened.  [No Power, Blank Screen, the Relay repeats ON
    OFF.]

  2. ASSY PDP MODULE P-X-MAIN: Vertically fitted on the right side of the panel,  look after back cover opend. [Blank Screen].

  3. ASSY PDP MODULE P-Y-MAIN:  Can be located on the Left side of the panel, next to Main AMPS. [Blank Screen]

  4. ASSY PDP MODULEP-LOGIC MAIN:  Can be located next below the SMPS power supply board. [Blank screen, Screen noise]

  5. ASSY PDP MODULEP-Y-MAIN SCAN BUFFER:  Can be located at the extreme left, fitted vertically. [Row Bar screen is blank]

  6. ASSY PDP MODULE P-ADDRESS E BUFFER: Can locate at the bottom left side. [Corresponding buffer Board block screen is blank]

  7. ASSY PDP MODULE P-ADDRESS F BUFFER: Can locate at the bottom right. [Corresponding buffer board Block screen is blank]

  8. ASSY PCB MISC-MAIN: Located just below the SMPS board. [No power,
    Abnormal screen for each input source, PIP screen trouble, Sound
    trouble]

  9. ASSY BOARD P-FUNCTION: Located extreme left down side. [The side function key does not properly]

  10. ASSY BOARD P-POWER&IR: Located at the bottom side [The remote
    control does not work properly, the LED does not work properly.

  11. ASSY BOARD P-SIDE AV: Located rigth bottom side [The AV-2 and S-Video 2 do not work properly]



DRIVE BOARD TROUBLESHOOTING



  • No voltage output => Operating voltage does not exists => PSU

  • No Display => Operating Voltage exists, but no image on screen => Y-MAIN, X-MAIN, Logic Main, Cable.

  • Abnormal Display => Abnormal image on screen, (Not open or short) => Y-MAIN, X-MAIN, Logic Main.

  • Sustain Open => Some horizontal lines does not exist on screen => Scan buffer, FPC of X/Y

  • Sustain short => Some horizontal lines appears to be linked on screen => Scan Buffer, FPC of X/Y

  • Address Open => Some vertical lines does not exist on screen => Logic Main, Logic Buffer, TCP

  • Address short => Some vertical lines appears to be linkde on screen => Logic Main, Logic Buffer, TCP



SERVICE MODE [WITH GENERAL REMOTE CONTROL]



TO ENTER SERVICE MODE:  POWER OFF=>MUTE=>1=>8=>2=>POWER ON


TO EXIT FROM SERVICE MODE: POWER OFF=>POWER ON


TO ENTER SERVICE MODE [WITH FACTORY REMOTE CONTROL]


POWER ON=> INFO=> FACTORY key


TO EXIT FROM SERVICE MODE


POWER OFF=>POWER ON


Press the factory key twice, with a keystroke interval of more than one second.[Pressing once enters Aging Mode].