LED BLINKING CODES - LG50PG20 - PLASMA TV - CONNECTOR VOLTAGE DETAILS











VISUAL CLUES FOR FAULT BY LED BLINKS


This information pertains to “Shorted” voltage lines, not
Open voltage lines




  • STBY 5V Short or Open: Power LED does not light in stand by.
    No Power button function.

  • AC Detect Open (Shorted Reset Line): Power LED is lit all
    Blue, 5V STBY OK. Power Button has no effect.

  • M5V Vcc Short: Apply AC Power, goes to flashing Red and
    Blue. Relay Clicks “On and Off”

  • 12V Short: Power LED is lit Red in stand by. At Power On,
    Power LED flashes 2 times Blue then 1 Long Blue goes back to Red. Relay clicks
    off immediately.

  • 16V Short: Apply AC Power , Power LED flashes Blue. Relay
    clicks rapidly on and off.

  • Va or Vs Short: Power LED is lit Red in stand by. At Power
    On, goes to Blue. Relay closes. Power LED blinks blue twice and3rd blink stays blue.
    Relay opens, LED goes to red. Power Supply outputs 16V,12V and 5Vcc,drops to 0V
    after the relay opens. No Va or Vs. With Relay closed, 330V OK, then when relay
    opens, it drops to 155V.


CN101 and P801 Pin ID and Voltages


Voltage and Diode Test Measurements for the SMPS.  All voltages from a working unit.


Connector: CN101


Pin Number: 1 & 3.


Standby: 120VAC


Run: 120VAC




Resistance: 480K




CLICK ON THE TABLES TO MAGNIFY